Standard Features
- 4 Stroke, 1500 RPM, water cooled heavy duty diesel engine
- Protection system on manuel run
- Flexible oil pipes and oil draining valve
- Pre-heater
- Lubrication oil and anti-freeze
- 4 Poles, synchrontype, single bearing, brushless alternatör
- Batteries and cables
- Electrostatic paint coated, steel, welded chassis
- Fuel tank housed in the chassis.
- Industrial type silencer
- Electronic battery charger
- Electrical wiring diagram
- User manual and operating manual
Optional Features
- Soundproof canopy
- Automatic transfer switch
- Circuit breaker
- Trailer
- External fuel tank
- Heating system for fuel tank
- Oil heater
- Fuel filling system ( Automatic / Manuel )
- Analog indicators
- 1 Phase - 3 Phase switch plugs
- Alarm system for fuel level
- Remote control and monitoring
Stand By Power : Supplying of emergency electrical power at variable load, in the event of normal utility power failure. This rating is maximum power, no overload capability is available.
Prime Power : Supplying of electrical power at variable load for an unlimited number of hours in the event of normal utility power failure. 10% over load capability is available.
GROUP |
||
Stand-by Power |
86 (68,8) |
kVA (kW) |
Prime Power |
77,4 (61,92) |
kVA (kW) |
Power Factor |
0,8 |
Cos Phi |
Frequency |
50 |
Hz |
ENGINE |
||
Make |
RICARDO |
|
Model |
R4105ZD |
|
Speed |
1500 |
rpm |
Prime Power |
59,5 (80,8) |
kW (HP) |
Stand-by Power |
71,4 (97) |
kW (HP) |
Number of Cylinders |
4 |
|
Cylinder Combination |
In-Line | |
Air Indication System |
Turbo | |
Cooling System |
Water Cooled | |
Governor Type |
Mechanic |
|
Cylinder Displacement |
4 |
lt |
Bore ve Stroke |
4-105x135 |
mm |
Compression Ratio |
16:1 |
|
Electric System |
24 V(DC) - 60 A |
|
Fuel Consumption %100 Loaded |
16 |
lt / h |
Fuel Consumption %75 Loaded |
12 |
lt / h |
Fuel Consumption %50 Loaded |
8 |
lt / h |
Fuel Tank Capasity |
192 |
Lt |
Fuel Type |
Dizel |
ALTERNATOR |
||
Make |
SKN |
|
Model |
SKNB-86 |
|
Type |
Synchron , Brushless | |
Prime Power |
77,4 (61,92) |
kVA (kW) |
Stand-by Power |
86 (68,8) |
kVA (kW) |
Overloaded |
1 hour per 12 hours %110 , 2 minute %120 |
|
Insulation Resistance |
Min.1800 |
V |
Short Circuit Current |
%300 10 Seconds |
|
Isolation Class |
H |
|
Drip Proof |
IP 23 |
|
Voltage |
231 / 400 V |
|
Tolerance of Voltage |
%0,5 |
DIMENSIONS |
||
Width (None-Cabine / Cabine) |
1000 (1000) |
mm |
Length (None-Cabine / Cabine) |
1950 (2470) |
mm |
Height (None-Cabine / Cabine) |
1400 (1630) |
mm |
Weight (None-Cabine / Cabine) |
1105 (1361) |
kg |