General Features
Advanced Microprocessor Control
Wide Input Voltage Range (160 - 260 VAC)
Advanced Fault Identification, 1000 pcs Alert/Event Memory
Advanced Communication Options with RS232 / RS485
True Online Double Conversion
100% Made in TURKEY
IGBT Rectifier and Inverter
Environment Friendly Design, The Most Silent in Its Class
Active Input Power Factor Correction (≥ 0.99)
Low Installation and Operation Costs
Low Input THDi <%3 Perfect Generator Compatibility
Easy Maintenance and Service
Low Output THDv <%3 Perfect Energy for your Loads
10 Years Spare Part Availability
Excellent Compability with Different Power Factor Loads
High Efficiency Up To 95%
Ultra High Efficiency with Smart Eco Mode (%98)
Reliable Parallel / Redundant Operation via Load Synchronization
GPRS Modem / CAN BUS Communication Options
Smart Fan Control
EMI / RFI Filter
Start on Battery Feature (Cold Start)
Short Circuit, High/Low Voltage and Overload Protections
Adjustable Time for Battery Operation
Selectable Input/Output Voltage and Frequency
Battery Deep Discharge Protection
Standard Static ve Maintenance By-Pass
Temperature Compensated Battery Charge, Selectable Charge Current
7/24 Technical Service and Customer Services
Optional Features
Advanced Remote Viewing and Management via SNMP
4 Programmable Dry Contacts
Easy Scalability with Parallelling
Microprocessor Controlled Smart Battery Management
Customizable Input/Output Options
Standards
EN 62040-1 (Safety), EN 62040-2 (EMC)
TSEK, CE, ISO 9001
| Model | ZIGANA | 
| Power ( kVA ) | 250 kVA | 
| INPUT | |
| Nominal Voltage / No. of Phases | 220/380 VAC / 230/400 VAC / 240/415 VAC (3 P + N) | 
| Voltage Range | ± 25% | 
| Nominal Frequency | 50 Hz / 60 Hz | 
| Frequency Range | ± 10% | 
| Input Power Factor | ≥ 99 | 
| THDi | < 3% | 
| OUTPUT | |
| Nominal Voltage / No. of Phases | 380 VAC / 400 VAC / 415 VAC (3 P + N) | 
| Voltage Tolerance | ± 1% | 
| Nominal Frequency | 50 Hz / 60 Hz | 
| Frequency Tolerance | 50 Hz ± 0,1% / 60 Hz ± 0,1% | 
| Power Factor | 0,8 Inductive (0.9 Optional) | 
| Crest Factor | 03:01 | 
| THDv | < 2% (Linear Load) < 4% (Non-Linear Load) | 
| Waveform | Pure Sine | 
| Overload Operation | 60 min. at 110% load / 10 min. at 125% load /1 min. at 150% load | 
| STATIC BY-PASS | |
| Voltage | 380 / 400 / 415 V ( 3 P + N ) | 
| Transfer Time | 0 ms. | 
| Overload Capacity | 150% | 
| BATTERY | |
| Voltage / Quantity | 1X50 12V | 
| Type | Maintenance Free Dry Type | 
| Charging Current | Selectable | 
| Temperature Compensated Charge | Microprocessor and Smart Sensor Controlled | 
| GENERAL | |
| Technology | On-Line Double Conversion | 
| Control | SPWM Controlled IGBT Rectifier and Inverter | 
| Efficiency | Up To 95% | 
| Parallel/Redundant Operation | Optional | 
| Protection | Overload, Over Temperature, Input/Output Short Circuit | 
| COMMUNICATION | |
| Display | 240 x 320 Graphical LCD ( Touch Screen Display ) | 
| Alert / Event Memory | 1000 pcs. | 
| Advanced Communication | RS232, 6 Programmable Dry Contacts, GPRS(Optional), SNMP ( Optional ) | 
| ENVIRONMENT | |
| Operating Temperature Range | 0 ˚C ~ 40 ˚C | 
| Relative Humidity | 0% – 95% ( Non-Condensing ) | 
| Altitute | ≤ 3000 m | 
| Noise | ≤ 50 dB | 
| Protection Class | IP20 | 