Lega Zigana Model 400 KVA UPS

General Features

Advanced Microprocessor Control

Wide Input Voltage Range (160 - 260 VAC)

Advanced Fault Identification, 1000 pcs Alert/Event Memory

Advanced Communication Options with RS232 / RS485

True Online Double Conversion              

100% Made in TURKEY

IGBT Rectifier and Inverter

Environment Friendly Design, The Most Silent in Its Class

Active Input Power Factor Correction (≥ 0.99)

Low Installation and Operation Costs

Low Input THDi <%3 Perfect Generator Compatibility

Easy Maintenance and Service

Low Output THDv <%3 Perfect Energy for your Loads

10 Years Spare Part Availability

Excellent Compability with Different Power Factor Loads

High Efficiency Up To 95%

Ultra High Efficiency with Smart Eco Mode (%98)

Reliable Parallel / Redundant Operation via Load Synchronization

GPRS Modem / CAN BUS Communication Options

Smart Fan Control

EMI / RFI Filter

Start on Battery Feature (Cold Start)

Short Circuit, High/Low Voltage and Overload Protections         

Adjustable Time for Battery Operation

Selectable Input/Output Voltage and Frequency           

Battery Deep Discharge Protection

Standard Static ve Maintenance By-Pass

Temperature Compensated Battery Charge, Selectable Charge Current

7/24 Technical Service and Customer Services

 

Optional Features

Advanced Remote Viewing and Management via SNMP

4 Programmable Dry Contacts

Easy Scalability with Parallelling

Microprocessor Controlled Smart Battery Management

Customizable Input/Output Options

 

Standards

EN 62040-1 (Safety), EN 62040-2 (EMC)

TSEK, CE, ISO 9001

Model

ZIGANA

Power ( kVA )

400 kVA

INPUT

Nominal Voltage / No. of Phases

220/380 VAC / 230/400 VAC / 240/415 VAC (3 P + N)

Voltage Range

± 25%

Nominal Frequency

50 Hz / 60 Hz

Frequency Range

± 10%

Input Power Factor

≥ 99

THDi

< 3%

OUTPUT

Nominal Voltage / No. of Phases

380 VAC / 400 VAC / 415 VAC (3 P + N)

Voltage Tolerance

± 1%

Nominal Frequency

50 Hz / 60 Hz

Frequency Tolerance

50 Hz ± 0,1% / 60 Hz ± 0,1%

Power Factor

0,8 Inductive (0.9 Optional)

Crest Factor

03:01

THDv

< 2% (Linear Load) < 4% (Non-Linear Load)

Waveform

Pure Sine

Overload Operation

60 min. at 110% load / 10 min. at 125% load /1 min. at 150% load

STATIC BY-PASS

Voltage

380 / 400 / 415 V ( 3 P + N )

Transfer Time

0 ms.

Overload Capacity

150%

BATTERY

Voltage / Quantity

1X50 12V

Type

Maintenance Free Dry Type

Charging Current

Selectable

Temperature Compensated Charge

Microprocessor and Smart Sensor Controlled

GENERAL

Technology

On-Line Double Conversion

Control

SPWM Controlled IGBT Rectifier and Inverter

Efficiency

Up To 95%

Parallel/Redundant Operation

Optional

Protection

Overload, Over Temperature, Input/Output Short Circuit

COMMUNICATION

Display

240 x 320 Graphical LCD ( Touch Screen Display )

Alert / Event Memory

1000 pcs.

Advanced Communication

RS232, 6 Programmable Dry Contacts, GPRS(Optional), SNMP ( Optional )

ENVIRONMENT

Operating Temperature Range

0 ˚C ~ 40 ˚C

Relative Humidity

0% – 95% ( Non-Condensing )

Altitute

≤ 3000 m

Noise

≤ 50 dB

Protection Class

IP20