Technical Details;
• Single phase
• Input: 130 VAC / 260 VAC, 100 VAC / 240 VAC
• Output: 220 VAC ±%5
• Efficiency: %96
• Regulation speed: 500 V/s
• Working conditions: -40°C / +60°C
• Protection: Low and high voltage protection, thermal protection
• Smart cooling fan
It can be used for;
• Wall Hung Water
• Boilers
•DVD Players
• Music Centres
• LCD & Plazma TV
• Satellite Receivers
•Etc. to obtain much better efficiency.
|
LEGA RELAY SERIES |
|
|
Power |
10 kVA |
|
Input Voltage Operation Interval |
130 – 260 V |
|
Frequency Average and Min,Max |
47 - 65 Hz |
|
Line Input Protection |
Low, High Voltage Protection |
|
Output Voltage |
220 VAC RMS ±2% |
|
Overloading |
10 Seconds 150 % Load |
|
Total Efficiency |
>96% |
|
Correction Speed |
500 Volt/Second |
|
Upturn Period |
500 Volt/Second |
|
Output Protection |
Protects Load by Opening The Circuit When Overload, Short Circuit Occurs |
|
Working Principle |
Relay Type |
|
Cooling |
Automatic Smart Fan System |
|
Full load |
8000 VA |
|
Demarrage load |
20000 VA |
|
Measured Value Monitor |
Input and Output Voltage Display Screen |
|
Mechanical By-Pass |
Manually Controlled Line |
|
MTBF |
200.000 hrs |
|
Protection Level |
IP 20 |
|
Operation Temperature |
-10 °C / 50 °C |
|
Storage Temperature |
-25 °C / 60 °C |
|
Short circuit (fuse) |
50 A |
|
High voltage protection Output |
245 V |
|
Start up time |
0,1 sec |
|
Input voltage display time |
0,1 sec |
|
Inner temperature display time |
2 sec |
|
Temperature display |
2 sec |
|
Relative Humidity |
<90 %, DIN (40040) |
|
Operation Altitude |
<2000 m |
|
Acoustic Level |
<50 dB (1 m²) |
|
Signal sound |
Start + Output + Temperature |
|
Usage |
Wall Mountable (Selectable) |
|
Warranty period |
2 year |
|
Dimensions |
|
|
W x D x H (cm) |
33 x 24 x 44 |
|
Weight (kg) |
28 |