PTL - 16 kVA

Standard Features

- 4 Stroke, 1500 RPM, water cooled heavy duty diesel engine

- Protection system on manuel run

- Flexible oil pipes and oil draining valve

- Pre-heater

- Lubrication oil and anti-freeze

- 4 Poles, synchrontype, single bearing, brushless alternatör

- Batteries and cables

- Electrostatic paint coated, steel, welded chassis

- Fuel tank housed in the chassis.

- Industrial type silencer

- Electronic battery charger

- Electrical wiring diagram

- User manual and operating manual

 

Optional Features

- Soundproof canopy

- Automatic transfer switch

- Circuit breaker

- Trailer

- External fuel tank

- Heating system for fuel tank

- Oil heater

- Fuel filling system ( Automatic / Manuel )

- Analog indicators

- 1 Phase - 3 Phase switch plugs

- Alarm system for fuel level

- Remote control and monitoring

 

Stand By Power : Supplying of emergency electrical power at variable load, in the event of normal utility power failure. This rating is maximum power, no overload capability is available.

Prime Power : Supplying of electrical power at variable load for an unlimited number of hours in the event of normal utility power failure. 10% over load capability is available.

GROUP

Stand-by Power

16 (12,8)

kVA (kW)

Prime Power

14,4 (11,52)

kVA (kW)

Power Factor

0,8

Cos Phi

Frequency

50

Hz

 

ENGINE

Make

PENTA

Model

P485

Engine Type

Diesel

Speed

1500

rpm

Prime Power

21 (28,5)

kW (HP)

Stand-by Power

23 (31,2)

kW (HP)

Number of Cylinders

4

Cylinder Combination

In-Line

Air Indication System

Natural Aspiration

Cooling System

Water Cooled

Governor Type

Mechanic

Cylinder Displacement

4

lt

Bore ve Stroke

90x100

mm

Compression Ratio

18:1

Electric System

12 V(DC) - 45 A

Fuel Consumption %100 Loaded

3.71

lt / sa

Fuel Consumption %75 Loaded

2.8

lt / sa

Fuel Consumption %50 Loaded

2

lt / sa

Fuel Tank Capasity

143

lt

Fuel Type

Diesel

 

ALTERNATOR

Make

SKN

Model

SKNA-16

Type

Synchron, Brushless

Prime Power

14,4 (11,52)

kVA (kW)

Stand-by Power

16 (12,8)

kVA (kW)

Overloaded

For 1 hour %110 in 12 hours, for 2 minutes %120

Insulation Resistance

Minimum 1800

V

Short Circuit Current

%300 10 Secaonds

Isolation Class

H

Drip Proof

IP 23

Voltage

231 / 400 V

V

Tolerance of Voltage

+-%0,5

 

DIMENSIONS

Width (None-Cabine / Cabine)

900 (900)

mm

Length (None-Cabine / Cabine)

1500 (1900)

mm

Height (None-Cabine / Cabine)

1250 (1370)

mm

Weight (None-Cabine / Cabine)

524 (726)

Kg