General Features
Advanced Microprocessor Control
True Online Double Conversion
IGBT Rectifier and Inverter
Real Digital Signal Processor Controlled Transformerless Design
Active Input Power Factor Correction (≥ 0.99)
Low Input THDi <%3 Perfect Generator Compatibility
Low Output THDv <%3 Perfect Energy for your Loads
Low Total Harmonic Distortion Level
Excellent Compability with Different Power Factor Loads
Selectable Input/Output Voltage and Frequency
Wide Input Voltage Range (160 - 260 VAC)
High Efficiency Up To 95%
Ultra High Efficiency with Smart Eco Mode (%98)
Reliable Parallel / Redundant Operation via Load Synchronization
Smart Fan Control
EMI / RFI Filter
Start on Battery Feature (Cold Start)
Short Circuit, High/Low Voltage and Overload Protections
Adjustable Time for Battery Operation
Battery Deep Discharge Protection
Standard Static ve Maintenance By-Pass
Temperature Compensated Battery Charge, Selectable Charge Current
Advanced Fault Identification, 1000 pcs Alert/Event Memory
Advanced Communication Options with RS232 / RS485
100% Made in TURKEY
Environment Friendly Design, The Most Silent in Its Class
Low Installation and Operation Costs
Easy Maintenance and Service
10 Years Spare Part Availability
7/24 Technical Service and Customer Services
Optional Features
Advanced Remote Viewing and Management via SNMP
4 Programmable Dry Contacts
GPRS Modem / CAN BUS Communication Options
Easy Scalability with Parallelling
Microprocessor Controlled Smart Battery Management
Customizable Input/Output Options
Standards
EN 62040-1 (Safety), EN 62040-2 (EMC)
TSEK, CE, ISO 9001
Model |
PLUS SERIES |
Power ( kVA ) |
200 kVA |
INPUT |
|
Number of Phases |
3 Phases + N + E |
Nominal Voltage / No. of Phases |
380 VAC / 410 VAC / 415 VAC (3 P + N) |
Voltage Range |
176 / 280 Vac. ± % 5 (at Full Load) |
Nominal Frequency |
50 Hz / 60 Hz |
Frequency Range |
± 10% |
Input Power Factor |
≥ 99 |
THDi |
< 5% |
OUTPUT |
|
Nominal Voltage / No. of Phases |
380 VAC / 400 VAC / 415 VAC (3 P + N) |
Voltage Tolerance |
± 1% |
Nominal Frequency |
50 Hz / 60 Hz |
Frequency Tolerance |
50 Hz ± 0,1% / 60 Hz ± 0,1% |
Power Factor |
0,8 |
Crest Factor |
03:01 |
THDv |
< 2% (Linear Load) < 4% (Non-Linear Load) |
Waveform |
Pure Sine |
Overload Operation |
60 min. at 110% load / 10 min. at 125% load /1 min. at 150% load |
STATIC BY-PASS |
|
Voltage Range |
175 – 253 VAC ( 3 P + N ) |
Transfer Time |
0 ms. |
Overload Capacity |
150% |
BATTERY |
|
Voltage / Quantity |
1X60 12V |
Type |
Maintenance Free Dry Type |
Charging Current |
Selectable |
Temperature Compensated Charge |
Microprocessor and Smart Sensor Controlled |
GENERAL |
|
Technology |
On-Line Double Conversion |
Control |
SPWM Controlled IGBT Rectifier and Inverter |
Efficiency |
Up To 95% |
Parallel/Redundant Operation |
Optional |
Protection |
Overload, Over Temperature, Input/Output Short Circuit |
COMMUNICATION |
|
Display |
240 x 320 Graphical LCD ( Touch Screen Display ) |
Alert / Event Memory |
1000 pcs. |
Advanced Communication |
RS232, 6 Programmable Dry Contacts, GPRS(Optional), SNMP ( Optional ) |
ENVIRONMENT |
|
Operating Temperature Range |
0 ˚C ~ 40 ˚C |
Relative Humidity |
0% – 95% ( Non-Condensing ) |
Altitute |
≤ 3000 m |
Noise |
≤ 50 dB |
Protection Class |
IP20 |
PHYSICAL SPECIFICATION |
|
Dimensions (W*D*H) |
110*82*160 cm |
Weight |
380 kgs |