General Features
Efficiency Up To 92%
Galvanic İsolation Transformer In Inverter Output
Emergency Shut-Down Switch Connection
Static By-Pass And Service By-Pass Feature
Detailed Data Monitoring And User-Defined Parameter Set- Ting By Means Of LCD İndicator
128 Recorded Event Memory (4000 Alarms)
Calendar And Clock İndicator
By Means Of Advanced Battery Management, Automatic And Manual Battery Test
Superior Performance For Non-Linear Loads (Computer Load)
Testing Communication Contacts By Simulation
Optional Features
Remote Monitoring From Networks And RS232 Communication Port To Switch Off Operating Systems Automatically And Safely And Dry Contact Outputs
Tailor-Made İnput/Output Values
SNMP-Compliant MODBUS-Compliant Communication
Parallel Operation Up To 4 Devices
Standards
Production With The Quality Assurance System Of CE, TSE, ISO9001 And ISO14001
2-Year System Warranty And 10-Year Spare Part Supply Warranty
MODEL |
T SERIES |
Power |
60 |
INPUT |
|
Voltage |
220 / 380 Vac (230/400 Vac) 3F + N + Ground ±%15 |
By-pass Voltage |
220 / 380 Vac (230/400 Vac) 3F + N ±%10 |
Frequency |
50 Hz. / 60 Hz. ± %5 |
EMI |
EN 62040-2 |
OUTPUT |
|
Power (kW) |
48 |
Power Factor |
0,8 |
Voltage |
380 / 400 VAC 3P + N |
Voltage Tolerance |
±%1 |
Voltage Recovery Time |
Max. 25msn. |
Frequency |
50 / 60 Hz |
Frequency Tolerance |
Line Synchronized ±%2 |
± 0,2 self-employment |
|
Efficiency (%100 load) |
%90 - 92 |
Crest Factor |
03:01 |
Overload |
%100 - 10 minutes at 125% load |
%125 - 10 minutes at 150% load |
|
>%150 load by-pass |
|
Short Circuit Protection |
Elektronik Short Circuit Protection |
THD |
<%3 (linear load) |
<%5 (non linear load) |
|
BATTERIES |
|
Type |
Full-closed dry type , Maintenance-free |
Number of Batteries |
30 |
Charge Voltage |
405 VDC |
End of Discharge Voltage |
300 VDC |
Operating temperature |
25ºC |
Battery protection |
Automatic Circuit Breaker |
Battery test |
Automatic Every 72 Hours |
GENERAL |
|
Seri Communication |
Dry contacts & RS232 |
Software |
T-MON UPS Remote Monitoring and Management Software |
Temperature Range |
0ºC - 40ºC |
Ventilation |
Forced cooling |
Humidity (Condensing) |
<%90 |
Protection Class |
IP20 |
Working Height |
<2000m. |
Noise Level |
< 56 dBA |
Weight Without battery |
496 |
Dimensions (WxDxH) |
575x820x1390 |
OPTIONS |
|
Input transformer |
Galvanic Isolation Transformer at The Input (in external cabinet) |
Input THDI |
%10 (with 12 Pulse or 18 Pulse rectifier, according to UPS range) |
%5 (18 Pulse rectifier, + filter), up to 100kVA) |
|
Input Power Factor |
0.95 - 0.98 (18 Pulse redresor with up to 100kVA) |
Parallel operation |
N+1 (up to 4) |
In 18 pulse % 12 pulse applications, the standard chassis dimensions may change |
|
Communication |
SNMP, MODBUS, Remote Mon. Panel, RS485 |