General Features
- Advanced Technology
- High- Advanced Technology
- High Performance via RISC Microprocessor Control
- Wide Power Options
- Wide Input Voltage Range
- True RMS Measurement, Feedback and Control
- Best in Class with 70-200 V/s Regulation Speed
- High Efficiency Up To 98%
- Independent Control Panel for Each Phase
- Selectable Output Max/Min Voltage
- Temparature Controlled Smart Cooling
- Short Circuit Protection
- 1024 pcs Alert/Event Memory
- Ease of Transfer of Load to Utility via Manual By-Pass
- Automatic Deactivate/Reactivate in Abnormal Conditions
- Independent/Together Operation of Phases
- High Performance Even on 100% Unbalanced Load
- Silent Operation
- Compact/Impact Resistant
- %100 Made in TURKEY
- Environment Friendly Design
- Small Dimensions
- Easy Installation/Maintenance and Service
- Low Installation and Operational Costs
- 10 Years Spare Part Availability
- 7/24 Technical Service and Customer Services
Optional Features
- Overload, High/Low Voltage, Over Temp. Protection
- Custom Design and Production for Client’ s Need
- Advanced Remote Viewing and Management via SNMP
Standards
- CE, ISO 9001:2015, ISO 14001:2015
Model |
Servo Regulator |
Power |
1 kVA |
INPUT |
|
Regulation Voltage Range |
110-240 / 160-260 /180-260 VAC (Selectable) |
In.Vol.Working Interval |
90 - 285 VAC |
Frequency |
47-65 Hz |
Line Input Protection |
Overcurrent, Low and High Voltage Protection |
OUTPUT |
|
Nominal Voltage |
220 / 230 / 240 VAC RMS ± 1% |
Overloading |
10 Sec. %200 Load |
Voltage Tolerance |
± 1% ( Selectable Between 1-8%) |
Frequency Range |
45-65 Hz |
THDv |
0% |
Correction Speed |
~90 Volt/Sec. |
Upturn Period |
~90 Volt/Sec. (160 VAC – 260 VAC) |
Output Protection |
Protects load by opening the circuit when overburden, short circuit occurs. |
GENERAL |
|
Technology |
Servo Motor, Microprocessor Controlled, Full Automatic Servo |
Control |
RISC Microprocessor, H-Bridge MOSFET PWM Motor Drive Technics |
Efficiency |
>96% |
Cooling |
Temperature Controlled Cooling System via Smart Fan System |
Protection |
Output Short Circuit, Overload, Output High / Low Voltage, Over Temperature, Motor Fault, Ground-Neutral (Optional) Protection |
Mechanic By-Pass |
Manual Mains/Regulator Breaker |
CONTROL PANEL |
|
Display |
2x16 Character LCD Display, Special LCD for each phase (Optional) |
Alert / Event Memory |
Mimic Diagram, Fault Warning LEDs / Real Time 1024 pcs Event/Alert Memory |
Monitorable Datas |
True RMS Input/Output Voltage, Load Percentage, Frequency Measurement |
COMMUNICATION |
|
Dry Contacts (Optional) |
Regulator Normal Operation(NO,C,NC); High/Low Output Voltage Warning (NO,C,NC) |
Remote Monitoring (Optional) |
Over Netwok/LAN (Optional) |
ENVIRONMENT |
|
Working Temperature |
-10 ˚C / 50 ˚C |
Storage Temperature |
-25 ˚C / 60 ˚C |
Relative Humidity |
< 90%, DIN (40040) |
Noise |
<50 Db (1 m²) |
Altitute |
≤ 3000 m |
Protection Class |
IP20 |
STANDARDS |
|
International Standards |
CE, ISO 9001:2008, ISO 14001:2015 |
DIMENSIONS |
|
W x D x H (cm) |
45 x 35 x 27 |
Weight (kg) |
15 |