Standard Features
- 4 Stroke, 1500 RPM, water cooled heavy duty diesel engine
- Protection system on manuel run
- Flexible oil pipes and oil draining valve
- Pre-heater
- Lubrication oil and anti-freeze
- 4 Poles, synchrontype, single bearing, brushless alternatör
- Batteries and cables
- Electrostatic paint coated, steel, welded chassis
- Fuel tank housed in the chassis.
- Industrial type silencer
- Electronic battery charger
- Electrical wiring diagram
- User manual and operating manual
Optional Features
- Soundproof canopy
- Automatic transfer switch
- Circuit breaker
- Trailer
- External fuel tank
- Heating system for fuel tank
- Oil heater
- Fuel filling system ( Automatic / Manuel )
- Analog indicators
- 1 Phase - 3 Phase switch plugs
- Alarm system for fuel level
- Remote control and monitoring
Stand By Power : Supplying of emergency electrical power at variable load, in the event of normal utility power failure. This rating is maximum power, no overload capability is available.
Prime Power : Supplying of electrical power at variable load for an unlimited number of hours in the event of normal utility power failure. 10% over load capability is available.
GROUP |
||
Stand-by Power |
44 (35,2) |
kVA (kW) |
Prime Power |
39,6 (31,68) |
kVA (kW) |
Power Factor |
0,8 |
Cos Phi |
Frequency |
50 |
Hz |
ENGINE |
||
Make |
PENTA |
|
Model |
P4102D |
|
Speed |
1500 |
rpm |
Prime Power |
39 (49) |
kW (HP) |
Stand-by Power |
40 (55) |
kW (HP) |
Number of Cylinders |
4 |
|
Cylinder Combination |
In-Line | |
Air Indication System |
Natural Aspiration | |
Cooling System |
Water Cooled | |
Governor Type |
Mechanic |
|
Cylinder Displacement |
3,85 |
Lt |
Bore ve Stroke |
102 x 118 |
Mm |
Compression Ratio |
18:1 |
|
Electric System |
12 V(DC) - 60 A |
|
Fuel Consumption %100 Loaded |
3,71 |
lt / h |
Fuel Consumption %75 Loaded |
2,8 |
lt / h |
Fuel Consumption %50 Loaded |
2 |
lt / h |
Fuel Tank Capasity |
171 |
Lt |
Fuel Type |
Dizel |
ALTERNATOR |
||
Make |
SKN |
|
Model |
SKNA-44 |
|
Prime Power |
39,6 (31,68) |
kVA (kW) |
Stand-by Power |
44 (35,2) |
kVA (kW) |
Overloaded |
1 hour per 12 hours %110 2 minute %120 |
|
Insulation Resistance |
Minimum 1800 |
V |
Short Circuit Current |
%300 10 seconds |
|
Isolation Class |
H |
|
Drip Proof |
IP 23 |
|
Voltage |
231 / 400 V |
|
Tolerance of Voltage |
%5 |
DIMENSIONS |
||
Width (None-Cabine / Cabine) |
1000 (1000) |
mm |
Length (None-Cabine / Cabine) |
1800 (2320) |
mm |
Height (None-Cabine / Cabine) |
1330 (1470) |
mm |
Weight (None-Cabine / Cabine) |
814 (1044) |
kg |