Lega DSP Model 10 KVA UPS

Transformerless UPS Topology

Low İnput Current Total Harmonic Distortion (THD)

High Input Power Factor

High Efficiency Up To 94%

Cold Start Function

Static And Maintenance By-Pass Switch

Output Short Circuit And Overload Protection

External REPO Switch Input

192 Events Memory (192 Events 4500 Alarms)

Clock And Calender (Battery Supported)

Automatic Battery Test,Remaining Battery Time Indicator

Temperature Compansated Charge System (Optional)

2 RS232 Serial Ports And 12 Dry Contact Outputs

3 DSP Controlled Modular Structure

Optional SNMP And MODBUS Adaptors

Optional Graphical Panel

Optional USB Flash Memory

Full Digital Structure

Small Footprint

Ecomode Operation (Optional)

Fewer Electronic Components

Output Current Limiting

Advanced Diagnostics For The İnput

Selectable Input/Output Voltage/Frequency/Range

Split By-Pass Input (Second Input)

Output DC Leakage Protection

Seperate DSP For İnverter Control

Seperate DSP For The PFC

3 Level Battery Protection

High Charge Current Capacity

Charge/Discharge Current İndicator

Advanced Remote Control

Manufactured According To EC Directive; EN62040

10 Years Spare Parts Support

2 Years Warranty

MODEL

DSP

Power (KVA)

10 Kva

Power (KW)

9 Kw

Power Factor

0,9

INPUT

Number Of Phases

3 Phase + Neutral

Input Voltage

220/380, 230/400 Or 240/415 Vac

Input Voltage Tolerance

+20% , -25% (+15% At 240/415Vac)

Input Power Factor (PF)

0,98 - 0,99 (At Full Load)

Input THDI

<= 5% (At Full Load)

Input Frequency

50 Hz. ±5%

By-Pass Voltage

220/380, 230/400 Or 240/415 Vac 3 Phase + Neutral

By-Pass Frequency

50 Hz. ±2%

RFI Level

EN62040-2

OUTPUT

Number Of Phases

3 Phase + Neutral

Output Voltage

220/380, 230/400 Or 240/415 Vac

Output Voltage Tolerance

±1%

Output Frequency

50 Hz.

Output Frequency Tolerance (Synchronous)

±2%

Output Frequency Tolerance (Battery)

±0,2%

Efficiency (100% Load)

Up To 94%

Load Crest Factor

3:1

Output Voltage THD (Linear Load)

<3%

Overload

125% Load 10min. , 150% Load 1min.

BATTERY

Total Number

60 Blocks 12V (2x30 Serial 60 Batteries)

Float Charge Voltage (250C)

± 405V DC

End Of Discharge Voltage

± 300V DC

Battery Test

Automatic And Manual

Boost Charge

Available

COMMUNICATION INTERFACES

RS232 Com Port

2 Each Standard (COM1 And COM2)

External Temperature Measurement Input

Available (Standard)

RS485 Comm. Port

Optional

Remote Monitoring Panel

Optional

SNMP Adapter

Optional

Modbus Adapter

Optional

Alarm Relay Contacts

4 Each Dry Contacts (Function Programmable) 8 Optional

Digital Inputs

2 Each Optional

Emergency Power-Off Input

Available (Standard)

ENVIRONMENT

Operating Temperature

0 – 400C

Operating Humidity

<= %90 (Non-Condensing)

Acoustic Noise

<55db

Dimensions (Wxdxh) (Mm)

400x815x1035

Device Type And Protection Class

Class 1  – IP20

Weight (Without Batteries) (App. Kgs)

87